OptionalanchorOptionalbuildingsOther buildings' footprints, fetched for the check's box (CheckOptions.otherBuildings when already resolved).
OptionalcellHazard raster cell size, metres. The provider's default when omitted. May not exceed half the provider's model cell: coarser cells can drop a thin flow path.
OptionalclassDepth resolution of the map's classes, metres. Default 0.25; may only be raised.
OptionalclearanceMinimum clearance margin in metres; raises the floor of 0.5 m, never lowers it.
Optionalgeoreference1-sigma vertical error of the model's height reference, metres, as the caller knows it (for example 0.05 for a surveyed map conversion). Default 0.5 when not stated: nothing in the model shows it was surveyed.
OptionalheightThe band the ground storey must lie in, and the entry tolerance; see plausibility.ts.
OptionalmaxLargest plan extent, metres, that the candidates, footprint and rings may
span before the check refuses (georeference-implausible): a building's
elements spread over kilometres means a wrong length unit or map scale.
Default 1000. A larger value yields results for a large site, but then the
georeference counts as unconfirmed and no element gets a favourable outcome.
OptionalotherOther buildings' footprints around the checked one, in the map's CRS.
Without them (or when they are not complete) transparent samples are
unknown: no element is no-runoff-mapped, and above-mapped-class-range
needs every sample to show a class (other-buildings-unknown).
OptionalsignalOptionalterrainTerrain grid resolution when the source offers grids, metres. Default 0.5; may only be made finer.
An element whose position lies further than this inside the footprint outline (metres) is anchored on the outline, but the ground there may not be the ground in front of it: no favourable outcome. Default 1.0; may only be lowered.